Olympus Bondmaster 1000e+, Bondtester, NDT, Eddy, Current Flaw Detector
The Olympus BondMaster 1000e+ allows users to select the best method for a particular application and to inspect a wide variety of composite materials. Its high performance, light weight, and rugged durability make it the ideal choice for applications related to the manufacturing, maintenance, and repair of composite materials.
With customer-interchangeable displays, the Olympus BondMaster 1000e+ offers users the highest resolution available today. The availability of a color or monochrome LCD for indoor or bright outdoor conditions, or a high-bright electroluminescent display (ELD) for normal to dark conditions provides the ultimate in flexibility and convenience. Its rugged, well-designed housing, uncomplicated front panel, SmartKnob, and built-in PowerLink technology make the BondMaster 1000e+ a truly revolutionary and user-friendly handheld portable flaw detector.
Features:
- Improved processor speed (up to 10 times faster)
- Full multimode capability:
– Pitch-catch (RF, impulse, swept)
– MIA (mechanical impedance analysis)
– Resonance - Customer-interchangeable displays:
– High-bright electroluminescent
– Monochrome liquid crystal
– Color liquid crystal - Improved screen displays:
– Split-screen displays (P-C RF, P-C impulse)
– Outdoor display - VGA output
- Field-replaceable Li-ion battery
- Lightweight, 2 kg (4.4 lb)
- USB output (via adapter) for printer or computer interface
- Alarm outputs
- Program and trace storage
- PowerLink technology provides automatic probe recognition and instrument setup
- High-voltage pitch-catch probes are available
Olympus BondMaster 1000e+ Specifications
General:
- Dimensions (L × H × D): 242 mm × 140 mm × 92 mm (9.5 in. × 5.5 in. × 3.6 in.)
- Weight: 2 kg (4.4 lb)
- Display: Customer-interchangeable QVGA displays (320 pixels x 240 pixels): color or monochrome LCD, high-bright electroluminescent
- Operating Temperature: −20°C to 60°C (−4°F to 140°F)
- Storage Temperature: −40°C to 80°C (−40°F to 176°F)
- Humidity: 95% ± 5%
- Classification: Complies with Class 2 specifications from the MIL-PRF-28800F Handbook.
- Altitude: Maximum operating and nonoperating altitude is 4,600 m (15,000 ft).
- Hazardous Area Operation: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Protection Association Code (NFPA 70), Section 500, and tested using MIL-STD-810F, Method 511.4, Procedure 1.
Power:
- Power: 7-pin connector to charge the internal batteries and operate the instrument from AC power
- Power Requirements: 85 V to 240 V, 50 Hz to 60 Hz mains. External holder charges batteries outside the instrument. Charging time is typically 4 h.
- Low Battery Protection: Display bar graph indicates approximate operating time.
- Battery Operating Time: 6 h to 8 h (nominal, depending on configuration)
Includes:
- Olympus BondMaster 1000e+ with Cover & Shoulder Strap
- BM1000e+ Probe Kit
- Olympus SP0-6886
- Olympus SP0-6887
- Sonic Cable Adapter VGA to Instrument Latching
- USB Serial Cable
- BondMaster SBM-CR-P6 Cable
- Energy Access Smart Battery Charger SBS 3002
- Universal Battery Charger
- Battery Charger Cable
- D-Cell Auxiliary Battery Pack
- Sonic BondMaster Software User’s Manual
- BondMaster 1000e+ User’s Manual
- BondMaster Installation CD Disc Version 2.6
- Power Supply
- (2) Power Cords
- Hard Case